November 2019
Daniel M. Weigl MD

In non-ambulatory patients with cerebral palsy, the presence of scoliosis has a major impact on health and quality of life. The aim of this review is to raise awareness of caregivers from various professions to the extent of the problem, to explain the natural history of neuromuscular scoliosis and its pathophysiology, and to describe up-to-date optional conservative and surgical treatments.

August 2019
Tal Frenkel Rutenberg MD, Yuval Baruch MD, Nissim Ohana MD, Hanna Bernstine MD, Amir Amitai MD, Nir Cohen MD, Liran Domachevsky MD and Shai Shemesh MD

Background: Implant-related spinal infections are a surgical complication associated with high morbidity. Due to infection, hardware removal may be necessary, which could lead to pseudarthrosis and the loss of stability and alignment.

Objectives: To evaluate the accuracy and diagnostic value of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in the workup of patients with suspected implant-related infections of the spine and to assess the clinical impact of PET/CT results on the management of these infections.

Methods: The study included nine consecutive patients with a history of spinal surgery who underwent PET/CT for evaluation of suspected spinal implant related infection. All imaging studies were performed between January 2011 and December 2013. All 18F-FDG PET/CT scans were performed on an 8 slice PET/CT following an 18F-FDG injection. Images were scored both visually and semi-quantitatively by a radiology expert. Results were compared to additional imaging studies when available, which were correlated to clinical and bacteriological findings allowing calculation of sensitivity, specificity and accuracy.

Results: Among the patients, five experienced hardware-related spinal infection. 18F-FDG PET/CT sensitivity was 80%, specificity 100%, and accuracy 88.9%. One scan produced a false negative; however, a second PET/CT scan revealed an infection.

Conclusions: PET/CT was found to be valuable for the diagnosis of postoperative hardware-related spinal infection, especially when other imaging modalities were uninformative or inconclusive. As such, PET/CT could be useful for management of infection treatment.

January 2003
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel